UL offers the health sciences industries a way to complete another required submission through one provider. UL’s non-clinical test services meet the requirements of the specifications generally accepted by the major global medical device markets. Working with UL for non-clinical testing provides the benefit of test plan consolidation, which can be faster than managing multiple test labs.

 

Biocompatibility

Biocompatibility is defined as “compatibility with living tissue or a living system by not being toxic, injurious, or physiologically reactive and not causing immunological rejection.” For medical devices, which come into contact with the human body for the purpose of treatment, diagnosis, or physical aid, making sure that every point of contact will not cause irritation, changes in blood composition, or toxic response is especially critical. Even if a material that makes up the medical device has been tested for biocompatibility, processes such as manufacturing, packaging, aging, and sterilization may have adverse affects on the material’s composition and how it reacts in different environments. Because of these potential changes, biocompatibility is an important test protocol that must be completed for every medical device end product prior to receiving global regulatory approvals.

UL offers our customers a comprehensive test package to satisfy requirements for global regulatory approvals.  For more information, click here.

 

Basic Microbiological Tests

Medical devices must be designed and manufactured in such a way as to eliminate or reduce the risk of microbial contamination as far as possible. Consequently, clean room facilities and manufactured devices must be subjected to regular bioburden determinations. Furthermore, the devices must be typically sterilized in validated procedures. UL can provide comprehensive testing including:

  • Bioburden determinations
  • Sterility tests
  • Environmental monitoring
  • Endotoxin determination
  • Validation of sterilization procedures

For more information, click here.

 

Virological Testing

According to ISO 22442, medical devices manufacturers must prove virological safety of their devices containing materials of animal origin. Therefore, the final product and/or the respective manufacturing processes must be subjected to virological validation studies.  UL has an established history in virological testing and validation of such manufacturing processes. UL can support selection of appropriate virus species and test procedures.  Find out more, click here.

 

Cleaning, Reprocessing, Sterilization

Numerous medical devices are subjected to a first-time cleaning process at the end of the manufacturing process. Such cleaning processes must be validated in view of the biocompatibility of the final product.

Reusable devices are subjected to a defined cleaning and disinfection process and are typically sterilized afterwards. UL can perform any of these process validations pursuant to ISO 17664 and can help select suitable “worst case” devices for testing.

 

Physical and Chemical Analyses

Physico-chemical analyses and mechanical test procedures are used to characterize medical devices pursuant to ISO 10993-18 and ISO/TIR10993-19. Also, potential surface contaminants as well as volatile and leachable chemical substances can be identified and evaluated toxicologically. Therefore, UL uses numerous modern analytical test procedures like GC/MS, HPLC, FTIR, ICP, XPS and SEM/EDX.  For more information, click here.

 

Shelf Life of Devices & Packages

According to ISO 11607-1, the specific properties of medical devices and their packaging systems must remain stable during their shelf life. Consequently, medical device manufacturers must perform appropriate validation studies in order to justify shelf life and transport stability of their devices. However, before these validations can take place, a validation of the forming and sealing process must be performed pursuant to ISO 11607-2.

In the course of a combined stability and packaging validation study, test devices are subjected to a thermal and regular ageing and to a transport simulation. Afterwards, the packages are subjected to various physical test systems, such as dye test for seal integrity, peel test, burst and creep test, air permeability test and test for microbiological tightness. Furthermore, the stressed medical devices are subjected to specific performance tests.  For more information, click here.

 

Testing of Ophthalmic Devices

We provide complete testing services for ophthalmic devices like contact lenses and lens care products, intraocular lenses and viscosurgical devices, which are highly regulated in numerous specific product standards.  For more information click here.

 

The UL advantage

  • Custom project planning — Our staff will work with you to prepare a project plan to meet your current and future product launch needs. This includes meeting with senior-level scientists with years of experience in preparing test protocols to meet regulatory submission requirements.
  • Experience — Through UL, you gain access to several decades of experience in analytical chemistry, biocompatibility, toxicology, bioanalytical, microbiological, pharmacology testing, and specialty services.
  • Global accreditation services — UL is a leader at getting our customers access to existing and emerging markets so you only need to work with one test, regulatory and certification provider to meet your global sales and distribution needs.

 